Citel AC combined surge arrester- / lightning arrester
Do you have a question about this product?
Our employee is happy to help you find the right product
- Product description
- Combined arrester type 1 + 2 + 3 based on a gas-filled spark gap
- 10 year guarantee
- Conductivity per pole: Iimp = 12.5 kA (10/350 μs)
- Safe disconnection device
- Saves energy costs; Does not generate (mains) follow-up current, operating and leakage current-free
- Meets the VDN guideline for use in the pre-meter area
- Can be used for lightning protection classes III + IV
- Remote signaling
- Meets the standards IEC 61643-11 and EN 61643-11
- Approved according to UL1449 ed.4
- Combined arrester type 1 + 2 + 3 based on a gas-filled spark gap
- For 40 mm busbar systems
- 10 year guarantee
- Conductivity per pole: Iimp = 8 kA (10/350 μs)
- Safe disconnection device
- Saves energy costs; Does not generate (mains) follow-up current, operating and leakage current-free
- Meets the VDN guideline for use in the pre-meter area
- Can be used for lightning protection classes III + IV
- Meets the standards IEC 61643-11 and EN 61643-11
- Reviews
- Shipping & returns
AC combined surge arrester- / lightning arrester
Multipole combination arrester type 1 + 2 + 3
DAC1-13VGS-31-275
The DAC1-13VG series with 12.5kA discharge capacity per pole is a space-saving and inexpensive solution for buildings of lightning protection classes III + IV. Thanks to the integrated CITEL VG technology, the DAC1-13VG, as a combined arrester type 1 + 2 + 3, combines all three protection classes in one device and thus offers optimal protection against lightning currents and overvoltages. The DAC1-13VG also meet the minimum requirements for type 1 lightning arresters according to VDE 0100-534 with a required discharge capacity of 12.5kA (10/350). The DAC1-13VG meet the VDN guidelines for lightning protection classes III + IV and can therefore be used in the pre-meter area. This makes the DAC1-13VG series ideally suited for installation in private, small and medium-sized commercial buildings.
ZPAC1-8VG-31-275
Der ZPAC1-8VG-31-275 mit 8 kA Ableitvermögen pro Pol ist eine platzsparende und günstige Lösung für Gebäude der Blitzschutzklassen III+IV und für die Montage auf 40 mm Sammelschienensysteme ausgelegt. Durch die integrierte CITEL VG-Technology vereint der ZPAC1-8VG-31-275 wie der DS250VG-300 als Kombi-Ableiter Typ 1+2+3 alle drei Schutzklassen in einem Gerät und bietet damit einen sehr guten Schutz gegen Überspannungen für die nachgelagerte Anlage. Der ZPAC1-8VG-31-275 erfüllt die VDN-Richtline bei Blitzschutzklasse III+IV und kann somit im Vorzählerbereich eingesetzt werden. Damit ist der ZPAC bestens geeignet zum Einbau in private und gewerbliche Gebäuden.
AC combined surge arresters / lightning arresters are installed in the meter cabinet and protect the house installation. See video.