Pylontech Battery Management SC1000-100S for high voltage Batteries
- Product description
- Protection against deep discharge and overcharging
- Protection against overvoltage during charging
- Deep discharge point at 10%
- Protection against excessive currents during charging and discharging
- Protection against over and under temperature
- Protection against short-circuit and reverse polarity
- Constant monitoring of the individual cell voltages (cell balance)
- protection against excessive discharge
- protection against overvoltage
- protection against overload
- Reviews
- Shipping & returns
BMS Control Unit SC1000-100S for Pylontech HV Lithiumbatterien
The BMS Pylontech Control Unit SC1000-100S is the matching battery management unit for the Pylontech HV batteriy H48050.
The SC1000-100S is the central control unit in a high-voltage battery storage system based on an
The SC1000-100S is the central control unit in a high-voltage battery storage system based on an iron phosphate lithium battery.
This is one of the new energy storage products that Pylontech has launched. The BMS offers a smaller footprint, less load and a long service life.
. This is one of the new energy storage products that Pylontech has launched. The control unit SC1000-100S offers a smaller footprint, less load and a long service life.
Advantages of a combination of SC1000-100S and Polytech iron phosphate lithium battery:
Administration and Control
System Advantages
It is possible to connect several HV batteries in series to increase the capacity of the storage system.
Some inverters have a working voltage range on the DC side e.g. of 100V-550V. When using a battery stack on such inverters, e.g. 3 pieces H48050 are required.
The battery management system (BMS) SC1000-100S has protective functions, including
protection against excessively high or low temperatures.
The system can automatically manage the charge and discharge status and balance the current and voltage of each cell. The control module has two types of power supply, either an internal power supply or an external power supply.
Technical Data
Controller Working Voltage | 100~435Vdc |
System Operation Voltage | 100~435Vdc |
Charge Current (Max.)(A) | 100 A |
Discharge Voltage(Vdc) | 100~435Vdc |
Discharge Current (Max.) | 100 A |
Self-Consumption Power (W) |
8 |
Dimension(W*D*H, mm) |
442*390*132 |
Communication |
RS485/CAN |
Protection Class |
IP20 |
Operation Life |
15 years |
Operation Temperature |
-20~65°C |
Storage Temperature |
-40~80°C |
Product Certificate |
TÜV(IEC62619) |